Pad to Pad (Spacing)

Reports electrically unconnected pads (in the same layer) closer than pp_spacing.

Internal ERF Name

<Area>:p2p

Measurement Shape

Measurement Value

Measurement ID

Spacing segment

Spacing

Pad1; Pad2

Layers Displayed

Signal layer

Graphic

Purpose

Close pads may bridge during imaging, etching, plating or soldering, and result in a direct short.

Function

Reports electrically unconnected pads (in the same layer) closer than pp_spacing. Measurements are segments, provided they only touch copper at its end points.

If classify_pad2pad=yes, the measurements reported are only between pads that are both non-drilled and non-SMD. If no, all measurements are reported here.

Does not report measurements involving features with attribute Copper Feature Ignore.

If the job was created directly from a CAD database, extra functionality is provided. A measurement between pads of the same CAD net, even if unconnected in the same layer, are placed in the ‘CAD Self Spacing’ category rather than the ‘Pad to Pad’ category.

ERF Parameters

pp_layer

pp_spacing

ERF Variables

classify_pad2pad

Constraint

Feature Spacing

Limitations