Internal ERF Name |
<Area>:coverage |
Measurement Shape Measurement ID |
Segment Spacing; Clearance |
Layers Displayed |
|
Graphic |
|
Purpose |
Lines which pass close to a pad must be fully covered by mask to avoid solder bridging between line and pad during the assembly process. |
Function |
Reports traces (or any other circuit features) closer than pp_coverage or touching a solder mask clearance that exposes a pad belonging to another net. Typically, each clearance has a signal intersecting it, a trace that touches exposed copper. If it does not connect to an inner pad, it is considered a violation. Unexposed copper, too close to a SM clearance with no exposed copper within, is always reported in this category. |
ERF Parameters |
pp_coverage |
ERF Variables |
cover_dist_to_cu cover_ignore_same_net cover_ignore_intersection cover_special_check v_report_proximity |
Constraint |
SM Feature Spacing |
Limitations |
To avoid false alarms near SMD picture frame openings and drawn areas, a filter is applied. If the distance to the other net exposed copper is greater than 1.5 times pp_coverage, the measurement is filtered. This causes coverage violations in oversized clearances to go unreported. |