All measurements are from edge to edge of copper, drill or clearance unless stated otherwise.
Category |
Description |
|---|---|
| NPTH to Copper (Drill) | Reports NPTHs closer than pp_d2c or touching copper. |
| PTH Annular Ring (Drill) | Reports the shortest distance between drill and laminate for PTHs embedded in copper if less than pp_d2c. |
| PTH to Copper (Drill) | Reports other net drills embedded in laminate if the distance from the edge of the drill to the nearest copper is less than pp_d2c. |
| Via to Copper (Drill) | Reports other net drills embedded in laminate if the distance from the edge of the drill to the nearest copper is less than pp_d2c. |
| PTH Contains Clearance (Drill) | Reports drills containing clearances on negative layers only. If clearance size is close to drill size, drill connectivity is degraded. |
| Via Contains Clearance (Drill) | Reports drills containing clearances on negative layers only. If clearance size is close to drill size, drill connectivity is degraded. |
| PTH to Plane (Drill) | Reports drills (embedded in copper) closer than pp_d2c to other net copper. |
| Via to Plane (Drill) | Reports drills (embedded in copper) closer than pp_d2c to other net copper. |
| NPTH to Plane (Drill) | Reports NPTHs closer than pp_d2c to other net copper. |
| NPTH Contains Copper (Drill) | Reports NPTHs containing copper on positive layers only. |
| Missing Cu for Vias (Drill) | Reports via holes not completely surrounded by copper in the drill layer with layer attribute Vias Need CU. |
| PTH Registration (Drill) | Reports the center-to-center distance between drills and touching pads, if larger reg_allowance and smaller than max_reg. |
| NPTH Registration (Drill) | Reports the center-to-center distance between drills and touching pads, if larger reg_allowance and smaller than max_reg. |
| Via Registration (Drill) | Reports the center-to-center distance between drills and touching pads, if larger reg_allowance and smaller than max_reg. |
| Sliver (Sliver) (Power and Ground) | Reports slivers, either between two copper areas (positive layer) or two clearance areas (negative layers) (usual case), whose width is less than pp_sliver, and non-zero. |
| Short Sliver (Sliver) (Power and Ground) | Reports slivers, either between two copper areas (positive layer) or two clearance areas (negative layers) (usual case). |
| Spoke Width (Thermal) | Reports thermal spoke (tie) widths in negative layers with flashed pads that are less than their defined widths. |
| Thermal Connect Reduction (Thermal) | Reports all incidents of thermal connectivity reduction in negative layers where thermal pads are flashed. |
| Plane Spacing (Plane Spacing) | Reports features in a positive or negative layer closer than pp_pln_spacing belonging to different plane nets if the measurement segment touches copper only at its endpoints. |
| Segmentation Lines (Plane Spacing) | Reports widths of actual laminate (spacing width) occupied by lines in negative layers only (lines in negative plane layers represent spacing), less than pp_pln_spacing. |